Material*

Pre-galvanized high tensile steel and EPS Foam Boards.

Insulation

ASTM C – 578. Reference Type II insulation 1.5#:

  • (75 degrees – 4.2 per inch) 6” = R–25.60, 8” = R-33.60
  • (40 degrees – 4.6 per inch) 6” = R-27.60, 8” = R-36.80
=
Depth Options
Available in depths ranging from 6 inches to 18 inches.
=
Load-Bearing Capacity
Up to 700 PSF
=

* Does not include welded wire mesh or concrete.

Built-In Thermal Performance

Foam insulation is integrated into the system, helping maintain indoor comfort and improving energy efficiency without extra steps or labor.

Faster Install Times

With insulation built right into the system, there’s no need for separate trades or extra steps. Just install the Super Floor System, add wire mesh and pour concrete.

Lightweight & Load-Efficient

The added insulation improves thermal performance without adding bulk. It’s a smart way to reduce load without giving up strength and performance.

No Shoring Required

Like our original Super Floor System,  this is a leave-in-place formwork design, requires zero temporary shoring, saving you time, labor, and coordination on-site. 

Long-Span Capability

Engineered for clear spans up to 34 feet, making it ideal for everything from safe rooms, to large commercial spaces and everything in between.

Works with Any Wall Type

The Super Floor System works seamlessly with ICF, CMU, poured-in-place concrete, wood, and steel framing. No special connections or compromises needed.

Connection Details

Connection Details for Architects & Engineers

Get the critical specs you need to plan with confidence.

Standard Joist Hanger Bracket (SUPFL-121)

Download:
PDF | DWG

Extended ICF Shoe Detail - Super Floor Extended Joist Hanger Bracket - 3 Hole

Extended Joist Hanger Bracket (SUPFL-123)

Download:
PDF | DWG

Instiu Beam Support - Super Floor Concrete Beam Connection Detail

Concrete Beam Connection Detail (SUPFL-301)

Download:
PDF | DWG

Perimeter Wall ICF - Super Floor Perimeter ICF Wall Connection Detail

Perimeter ICF Wall Connection Detail (SUPFL-302)

Download:
PDF | DWG

Internal Wall ICF Detail - Super Floor Internal ICF Wall Connection Detail

Internal ICF Wall Connection Detail (SUPFL-303)

Download:
PDF | DWG

Steel Beam Support - Super Floor Internal Steel Beam Connection Detail

Internal Steel Beam Connection Detail (SUPFL-304)

Download:
PDF | DWG

Masonry Wall Support - Super Floor External CMU Wall Connection Detail

External CMU Wall Connection Detail (SUPFL-305)

Download:
PDF | DWG

Internal Masonry Wall - Super Floor Internal CMU Wall Connection Detail

Internal CMU Wall Connection Detail (SUPFL-306)

Download:
PDF | DWG

Edge Support for Masonry Wall - Super Floor Wall Support Angle Connection Detail

Wall Support Angle Connection Detail (SUPFL-307)

Download:
PDF | DWG

Timber Wall Support - Super Floor Timber Wall Connection Detail

Timber Wall Connection Detail (SUPFL-308)

Download:
PDF | DWG

Timber Wall Support - Super Floor Timber Wall Connection Detail

Metal Stud External Wall Connection Detail (SUPFL-310)

Download:
PDF | DWG

Load/Span Tables

Essential Insights into Load/Span Capacities

Download Load/Span Tables Here.
Slab Topping Joist Size 40 PSF LL/Joist Spacing (ft) 50 PSF LL/Joist Spacing (ft)
2' 3' 4' 5' 2' 3' 4' 5'
3.5" 6" 16'-7" 14'-8" 13'-4" 12'-4" 16'-3" 14'-6" 13'-2" 12'-2"
8" 20'-4" 18'-1" 16'-7" 15'-6" 20'-2" 17'-10" 16'-3" 15'-2"
10" 24'-0" 21'-3" 19'-6" 18'-2" 23'-7" 21'-0" 19'-2" 17'-10"
12" 27'-3" 24'-3" 22'-1" 20'-6" 27'-0" 23'-10" 21'-10" 20'-3"
14" 30'-6" 26'-9" 24'-6" 22'-8" 30'-2" 26'-7" 24'-2" 21'-2"
16" 33'-4" 29'-5" 26'-10" 25'-0" 33'-0" 29'-1" 26'-6" 24'-3"
18" 34'-0" 31'-10" 29'-2" 27'-1" 34'-0" 31'-6" 28'-8" 26'-8"
4.0" 6" 16'-2" 14'-3" 13'-0" 12'-1" 16'-0" 14'-1" 12'-10" 12'-0"
8" 19'-10" 17'-7" 16'-1" 15'-0" 19'-8" 17'-4" 15'-10" 14'-9"
10" 23'-6" 20'-9" 19'-0" 17'-8" 23'-2" 20'-6" 18'-9" 17'-6"
12" 26'-9" 23'-9" 21'-8" 20'-3" 26'-6" 23'-6" 21'-6" 20'-0"
14" 30'-0" 26'-7" 24'-4" 21'-9" 28'-6" 26'-0" 23'-7" 20'-6"
16" 33'-1" 29'-4" 26'-9" 24'-9" 32'-7" 29'-0" 26'-6" 23'-6"
18" 34'-0" 31'-8" 29'-0" 27'-0" 33'-6" 31'-6" 28'-8" 25'-8"
Slab Topping Joist Size 80 PSF LL/Joist Spacing (ft) 100 PSF LL/Joist Spacing (ft)
2' 3' 4' 5' 2' 3' 4' 5'
3.5" 6" 15'-7" 13'-10" 12'-8" 11'-6" 14'-10" 13'-6" 11'-10" 10'-7"
8" 19'-3" 17'-2" 15'-8" 14'-3" 18'-10" 16'-8" 14'-9" 13'-3"
10" 22'-9" 20'-2" 18'-6" 16'-7" 22'-3" 19'-8" 17'-2" 15'-4"
12" 25'-6" 23'-0" 20'-7" 18'-6" 25'-3" 22'-1" 19'-2" 17'-1"
14" 28'-10" 24'-0" 22'-6" 20'-3" 28'-2" 24'-2" 20'-8" 18'-6"
16" 31'-9" 28'-1" 24'-7" 22'-0" 31'-2" 25'-5" 22'-9" 20'-4"
18" 34'-0" 30'-6" 26'-6" 23'-6" 33'-6" 28'-2" 24'-7" 20'-7"
4.0" 6" 15'-4" 13'-6" 12'-3" 11'-0" 15'-0" 13'-2" 11'-3" 10'-2"
8" 19'-0" 16'-7" 15'-4" 13'-8" 18'-2" 16'-3" 14'-2" 12'-8"
10" 22'-3" 19'-11" 18'-2" 16'-6" 22'-0" 19'-4" 17'-2" 15'-4"
12" 25'-4" 22'-7" 20'-7" 18'-6" 23'-7" 22'-2" 19'-3" 17'-3"
14" 28'-2" 23'-9" 22'-0" 20'-1" 27'-10" 23'-6" 20'-5" 18'-5"
16" 31'-6" 28'-0" 24'-7" 21'-9" 30'-8" 26'-7" 22'-8" 20'-5"
18" 34'-0" 30'-6" 26'-6" 23'-5" 33'-7" 28'-5" 24'-7" 21'-2"
Slab Joist 40 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 16'-7" 14'-8" 13'-4" 12'-4"
8" 20'-4" 18'-1" 16'-7" 15'-6"
10" 24'-0" 21'-3" 19'-6" 18'-2"
12" 27'-3" 24'-3" 22'-1" 20'-6"
14" 30'-6" 26'-9" 24'-6" 22'-8"
16" 33'-4" 29'-5" 26'-10" 25'-0"
18" 34'-0" 31'-10" 29'-2" 27'-1"
4.0" 6" 16'-2" 14'-3" 13'-0" 12'-1"
8" 19'-10" 17'-7" 16'-1" 15'-0"
10" 23'-6" 20'-9" 19'-0" 17'-8"
12" 26'-9" 23'-9" 21'-8" 20'-3"
14" 30'-0" 26'-7" 24'-4" 21'-9"
16" 33'-1" 29'-4" 26'-9" 24'-9"
18" 34'-0" 31'-8" 29'-0" 27'-0"
Slab Joist 50 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 16'-3" 14'-6" 13'-2" 12'-2"
8" 20'-2" 17'-10" 16'-3" 15'-2"
10" 23'-7" 21'-0" 19'-2" 17'-10"
12" 27'-0" 23'-10" 21'-10" 20'-3"
14" 30'-2" 26'-7" 24'-2" 21'-2"
16" 33'-0" 29'-1" 26'-6" 24'-3"
18" 34'-0" 31'-6" 28'-8" 26'-8"
4.0" 6" 16'-0" 14'-1" 12'-10" 12'-0"
8" 19'-8" 17'-4" 15'-10" 14'-9"
10" 23'-2" 20'-6" 18'-9" 17'-6"
12" 26'-6" 23'-6" 21'-6" 20'-0"
14" 28'-6" 26'-0" 23'-7" 20'-6"
16" 32'-7" 29'-0" 26'-6" 23'-6"
18" 33'-6" 31'-6" 28'-8" 25'-8"
Slab Joist 80 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 15'-7" 13'-10" 12'-8" 11'-6"
8" 19'-3" 17'-2" 15'-8" 14'-3"
10" 22'-9" 20'-2" 18'-6" 16'-7"
12" 25'-6" 23'-0" 20'-7" 18'-6"
14" 28'-10" 24'-0" 22'-6" 20'-3"
16" 31'-9" 28'-1" 24'-7" 22'-0"
18" 34'-0" 30'-6" 26'-6" 23'-6"
4.0" 6" 15'-4" 13'-6" 12'-3" 11'-0"
8" 19'-0" 16'-7" 15'-4" 13'-8"
10" 22'-3" 19'-11" 18'-2" 16'-6"
12" 25'-4" 22'-7" 20'-7" 18'-6"
14" 28'-2" 23'-9" 22'-0" 20'-1"
16" 31'-6" 28'-0" 24'-7" 21'-9"
18" 34'-0" 30'-6" 26'-6" 23'-5"
Slab Joist 100 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 14'-10" 13'-6" 11'-10" 10'-7"
8" 18'-10" 16'-8" 14'-9" 13'-3"
10" 22'-3" 19'-8" 17'-2" 15'-4"
12" 25'-3" 22'-1" 19'-2" 17'-1"
14" 28'-2" 24'-2" 20'-8" 18'-6"
16" 31'-2" 25'-5" 22'-9" 20'-4"
18" 33'-6" 28'-2" 24'-7" 20'-7"
4.0" 6" 15'-0" 13'-2" 11'-3" 10'-2"
8" 18'-2" 16'-3" 14'-2" 12'-8"
10" 22'-0" 19'-4" 17'-2" 15'-4"
12" 23'-7" 22'-2" 19'-3" 17'-3"
14" 27'-10" 23'-6" 20'-5" 18'-5"
16" 30'-8" 26'-7" 22'-8" 20'-5"
18" 33'-7" 28'-5" 24'-7" 21'-2"
Slab Topping Joist Size 40 PSF LL/Joist Spacing (ft) 50 PSF LL/Joist Spacing (ft)
2' 3' 4' 5' 2' 3' 4' 5'
3.5" 6" 15'-6" 13'-8" 12'-7" 11'-10" 15'-3" 13'-7" 12'-6" 11'-7"
8" 19'-1" 17'-0" 15'-7" 14'-6" 19'-0" 16'-9" 15'-4" 14'-4"
10" 22'-6" 20'-0" 18'-3" 17'-1" 22'-3" 19'-8" 18'-1" 16'-10"
12" 25'-5" 22'-9" 20'-10" 19'-7" 25'-2" 22'-7" 20'-8" 19'-4"
14" 28'-8" 25'-6" 23'-3" 21'-8" 28'-2" 25'-3" 23'-1" 21'-6"
16" 31'-8" 28'-0" 25'-6" 23'-9" 31'-4" 27'-7" 25'-4" 23'-6"
18" 34'-0" 30'-3" 27'-8" 25'-9" 33'-6" 30'-1" 27'-4" 25'-6"
4.0" 6" 15'-3" 13'-4" 12'-3" 11'-4" 15'-0" 13'-4" 12'-1" 11'-4"
8" 18'-7" 16'-5" 15'-1" 14'-1" 18'-6" 16'-5" 15'-0" 14'-0"
10" 22'-0" 19'-5" 17'-11" 16'-7" 21'-9" 19'-4" 17'-8" 16'-6"
12" 25'-1" 22'-4" 20'-5" 19'-1" 24'-10" 22'-1" 20'-2" 18'-10"
14" 28'-6" 25'-0" 22'-10" 21'-5" 27'-10" 24'-8" 22'-8" 21'-3"
16" 31'-0" 27'-7" 25'-3" 23'-7" 30'-10" 27'-4" 25'-1" 23'-4"
18" 33'-8" 30'-1" 27'-7" 25'-7" 33'-7" 29'-10" 27'-4" 25'-4"
Slab Topping Joist Size 80 PSF LL/Joist Spacing (ft) 100 PSF LL/Joist Spacing (ft)
2' 3' 4' 5' 2' 3' 4' 5'
3.5" 6" 14'-10" 13'-2" 12'-1" 11'-3" 14'-8" 13'-0" 11'-10" 10'-2"
8" 18'-4" 16'-3" 15'-0" 14'-0" 18'-1" 16'-1" 14'-7" 12'-10"
10" 21'-8" 19'-2" 17'-6" 16'-1" 21'-3" 18'-10" 17'-2" 15'-4"
12" 24'-7" 21'-10" 20'-1" 18'-5" 24'-4" 21'-6" 19'-3" 17'-3"
14" 27'-5" 24'-6" 22'-6" 20'-3" 27'-2" 23'-8" 21'-3" 19'-0"
16" 30'-6" 27'-1" 24'-6" 22'-0" 30'-0" 26'-3" 23'-1" 20'-6"
18" 33'-2" 29'-3" 26'-6" 23'-7" 32'-7" 28'-3" 24'-7" 22'-0"
4.0" 6" 14'-6" 12'-9" 11'-10" 11'-0" 14'-4" 12'-7" 11'-4" 10'-2"
8" 18'-0" 16'-0" 14'-7" 13'-7" 17'-6" 15'-6" 14'-3" 12'-10"
10" 21'-3" 18'-10" 17'-3" 16'-0" 21'-0" 18'-7" 17'-0" 15'-4"
12" 24'-3" 21'-6" 19'-7" 18'-4" 23'-10" 21'-2" 19'-1" 17'-3"
14" 27'-2" 24'-1" 22'-1" 19'-8" 26'-8" 23'-7" 21'-2" 19'-0"
16" 30'-0" 26'-6" 24'-4" 21'-9" 29'-7" 26'-2" 23'-0" 20'-6"
18" 32'-8" 29'-1" 26'-5" 23'-1" 32'-2" 28'-2" 24'-7" 22'-2"
Slab Joist 40 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 15'-6" 13'-8" 12'-7" 11'-10"
8" 19'-1" 17'-0" 15'-7" 14'-6"
10" 22'-6" 20'-0" 18'-3" 17'-1"
12" 25'-5" 22'-9" 20'-10" 19'-7"
14" 28'-8" 25'-6" 23'-3" 21'-8"
16" 31'-8" 28'-0" 25'-6" 23'-9"
18" 34'-0" 30'-3" 27'-8" 25'-9"
4.0" 6" 15'-3" 13'-4" 12'-3" 11'-4"
8" 18'-7" 16'-5" 15'-1" 14'-1"
10" 22'-0" 19'-5" 17'-11" 16'-7"
12" 25'-1" 22'-4" 20'-5" 19'-1"
14" 28'-6" 25'-0" 22'-10" 21'-5"
16" 31'-0" 27'-7" 25'-3" 23'-7"
18" 33'-8" 30'-1" 27'-7" 25'-7"
Slab Joist 50 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 15'-3" 13'-7" 12'-6" 11'-7"
8" 19'-0" 16'-9" 15'-4" 14'-4"
10" 22'-3" 19'-8" 18'-1" 16'-10"
12" 25'-2" 22'-7" 20'-8" 19'-4"
14" 28'-2" 25'-3" 23'-1" 21'-6"
16" 31'-4" 27'-7" 25'-4" 23'-6"
18" 33'-6" 30'-1" 27'-4" 25'-6"
4.0" 6" 15'-0" 13'-4" 12'-1" 11'-4"
8" 18'-6" 16'-5" 15'-0" 14'-0"
10" 21'-9" 19'-4" 17'-8" 16'-6"
12" 24'-10" 21'-1" 20'-2" 18'-10"
14" 27'-10" 24'-8" 22'-8" 21'-3"
16" 30'-10" 27'-4" 25'-1" 23'-4"
18" 33'-7" 29'-10" 27'-4" 25'-4"
Slab Joist 80 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 14'-10" 13'-2" 12'-1" 11'-3"
8" 18'-4" 16'-3" 15'-0" 14'-0"
10" 21'-8" 19'-2" 17'-6" 16'-1"
12" 24'-7" 21'-10" 20'-1" 18'-5"
14" 27'-5" 24'-6" 22'-6" 20'-3"
16" 30'-6" 27'-1" 24'-6" 22'-0"
18" 33'-2" 29'-3" 26'-6" 23'-7"
4.0" 6" 14'-6" 12'-9" 11'-10" 11'-0"
8" 18'-0" 16'-0" 14'-7" 13'-7"
10" 21'-3" 18'-10" 17'-3" 16'-0"
12" 24'-3" 21'-6" 19'-7" 18'-4"
14" 27'-2" 24'-1" 22'-1" 19'-8"
16" 30'-0" 26'-6" 24'-4" 21'-9"
18" 32'-8" 29'-1" 26'-5" 23'-1"
Slab Joist 100 PSF LL/Joist Spacing (ft)
2' 3' 4' 5'
3.5" 6" 14'-8" 13'-0" 11'-10" 10'-2"
8" 18'-1" 16'-1" 14'-7" 12'-10"
10" 21'-3" 18'-10" 17'-2" 15'-4"
12" 24'-4" 21'-6" 19'-3" 17'-3"
14" 27'-2" 23'-8" 21'-3" 19'-0"
16" 30'-0" 26'-3" 23'-1" 20'-6"
18" 32'-7" 28'-3" 24'-7" 22'-0"
4.0" 6" 14'-4" 12'-7" 11'-4" 10'-2"
8" 17'-6" 15'-6" 14'-3" 12'-10"
10" 21'-0" 18'-7" 17'-0" 15'-4"
12" 23'-10" 21'-2" 19'-1" 17'-3"
14" 26'-8" 23'-7" 21'-2" 19'-0"
16" 29'-7" 26'-2" 23'-0" 20'-6"
18" 32'-2" 28'-2" 24'-7" 22'-2"
Design Considerations

Structural Design Conditions

  • Tables are based on a SDL of 10 PSF and Construction Live Load of 20 PSF
  • Concrete compressive strength 4000 psi
  • Joists are rolled from 2.97BMT material (SS50-G90 Galvanized steel)
  • First joist hole to be min. 4’ from joist end
  • Joists are precambered 0.015" per 10' length
  • Vibration not considered for span tables
  • Dead loads include weight of concrete
  • No propping required during slab placement
  • Capacities per ANSI/AISI S100-12 LRFD

Concrete Properties

  • Minimum 3500 PSI

Loading

  • Installed Floor Dead Load is 50 PSF (with 4" topping)
  • Suspended Slab over ‘Super Floor’ Joists
  • 3.5” thick slab U.N.O.
  • 6 - 6, 4.0 x 4.0 WWM, ASTM A1064, GRADE 70
  • #4 Rebar Beam and Slab Edges TYP

General Notes

  • No point load > 3000 lbs on Super Floor slab
  • Span Tables are for estimating only
  • Stairs, columns, and beams by others
  • Concrete Beams poured before Super Floor install
Manufacturing

Manufactured in the USA,
Shipped Everywhere

All Super Floor components are proudly made in the USA using high-quality, galvanized steel. By keeping production in-house, we ensure consistent quality and faster turnaround times. Whether your project is across the country or across the world, we’ll ship everything organized, labeled, and palletized—so it arrives on time and ready to install.

Super Floor USA Made In USA
Projects

Real Projects With Real Results

From custom homes to commercial builds, Super Floor helps people save time, cut costs, and deliver lasting results. See how it’s making a difference on real job sites.

F.A.Q.

Got Questions?
We’ve Got Answers

Below are some of our frequently asked questions about our product and company. View all Questions →

Super Floor USA - Nick Ruebel

Have other questions?

Just reach out—we’re here to help!
Contact us →

What is the lead time from acceptance?
It depends on the scope of the project but for a residential job under 8,000 sq ft. We can ship typically in 4-6 weeks.
Where is Super Floor USA located?
The company and manufacturing is headquartered in Batavia, Ohio USA.
How thick should the concrete be?
A minimum of three and a half inches is recommended, but four inches offers a more rigid floor.
What's the maximum span?
We can span up to 30 ft depending on the load requirements.
What materials are used in the Super Floor system?
The system uses high-tensile galvanized steel joists and trays with G110 coating for trays and G90 for joists and lock bars to be corrosion resistant.
What wall systems are compatible with Super Floor?
Super Floor can be used for a variety of building types, including ICF structures, Steel frame buildings, masonry buildings, poured in-situ, and precast concrete.
What is the typical joist spacing for Super Floor systems?
Joist spacing varies from 1 to 5 feet, depending on load requirements and design specifications.

Save Time. Cut Costs. Start Today.

From faster construction timelines to lower labor costs, see what Super Floor can do for your project—starting with a free estimate.

Free estimate. No obligation. No pressure.